SPECTRA i.NET REPORTS MANUAL
SETTING INDIVIDUAL SOUND VALUES
MaskingValues:
Masking values consist of MaskLevel, MaskContour, and MaskMuted. The level is the loudness of the masking,
and ranges from 34dB (lowest volume) to 82.5dB (highest volume) in 0.5dB intervals. 58.5 dB is the default set-
ting. Contour refers to pink or white noise. This value ranges from -14 (pink noise) to +14 (white noise) in 0.5 step
intervals. 7 is the default setting. “Mask Muted” controls muting of the masking. It accepts “Yes” or “No”. “No” is
the default setting.
In the mock i.Net setup, OP 1’s channel A is set at the maximum loudness with middle contour, channel B is set at
the minimum loudness with slightly white contour, channel C is muted, and channel D is set for medium loudness
with slightly white contour.